This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site.
Thank you very much
Item / Preparation +B SET-UP
1. 2.
ADJUSTMENT PROCEDURE
Receive a Window pattern. Set the controls : Brightness Contrast Volume Minimum Minimum Minimum
Adjustments
TPD11
Confirm the following voltages: 12,3 13,5 TPD12 TPD13 TPD16 TPD17 TPD20 3,3 5 8 3,3 1,8
Audio 5W Audio MIN
± ± ± ± ± ± ±
0,5V 0,5V 0,15V 0,25V 0,3V 0,15V 0,1V
TPD21
9,4 5,7
Normal mode Standby mode
±
0,5V 0,3V 1,5V 10V 1V 1V 1V 0,3V
±
TPD23 TPD121 TPD122 TPD123 TPD124 TPL5
138 205 17,2 -11,6 13,6 6,3
± ± ± ± ± ±
CUT OFF / Ug2 Test
1. Receive a Window pattern. 3. Set: Colour 50% Brightness 50% Contrast 100%
To adjust Cutoff connect an oscilloscope to the Blue cathode. Adjust the screen VR until the black level is 160V ± 2V.
Black Level 160V ± 2V GND
SELF CHECK
Self-check is used to automatically check the bus lines and hexadecimal code of the TV set.To enter Self-Check mode, press the STATUS button on the remote control and at the same time press the down (-/v) button on the customer controls at the front the TV set. To exit Self Check, switch off the TV set at the power button.
E2 DDP VSP AVSW
O.K. O.K. O.K. O.K.
TUN MSP DPL MAS VCTi
O.K. O.K. ----F1 TX-28PN1F TX-28PN1P 0F 00 B0 11 00 35 7F 54 00 00 11 00 88 71
TX-29PN1D OPTION 1 OPTION 2 OPTION 3 OPTION 4 OPTION 5 OPTION 6 OPTION 7 OPTION 8 OPTION 9 OPTION 10 OPTION 11 OPTION 12 OPTION 13 CHECK 0F 00 A0 11 00 35 7F D4 00 00 11 00 88 E1
TX-29PN1F TX-29PN1P 0F 00 A0 11 00 35 7F 54 00 00 11 00 88 61
TX-28PN1D 0F 00 B0 11 00 35 7F D4 00 00 11 00 88 F1
If the CCU ports have been checked and found to be incorrect or not located then " - - " will appear in place of "O.K.".